Definition
Measures the percentage of automated calibration events that created a measurable quality discontinuity in the production output.
The Measurement Gap
Automated calibration systems correct tool drift by adjusting measurements or machine settings to match a reference standard. The correction itself is correct, meaning the tool is now producing output at the intended target rather than at the drifted position. However, the correction creates a step-change in the production output. Parts produced before calibration were at the drifted position. Parts produced after calibration are at the corrected position. If the drift was significant and the correction happens mid-lot, the lot now contains parts at two different dimensional positions, both potentially within specification but inconsistent with each other.
No existing metric measures this discontinuity because calibration systems are evaluated on whether the calibration was accurate, not on whether it created a production consistency problem. Quality systems are evaluated on whether parts are within specification, not on whether the dimensional distribution shifted between calibration events. CIDR measures the production impact that neither system tracks: did the calibration correction create a step-change large enough to matter for downstream assembly, lot consistency, or process control chart interpretation? This metric enables data-driven decisions about whether calibrations should be timed to lot boundaries rather than firing mid-production.
Formula
CIDR divides the count of calibration events that caused a quality discontinuity by the total count of calibration events, expressed as a percentage.
CIDR = Calibrations_with_discontinuity / Calibrations_total times 100
Where Calibrations_with_discontinuity is the count of automated calibration events where the pre-calibration to post-calibration quality metric shift exceeds the discontinuity threshold. Calibrations_total is all automated calibration events in the measurement period. The discontinuity threshold is configurable but a recommended default is a quality metric shift exceeding 20% of the tolerance band.
A CIDR of 0% means no calibrations create quality discontinuities, which is the ideal state where either drift is minimal or calibrations are timed to lot boundaries. Higher values indicate more discontinuity risk. The critical distinction is that the calibration itself is correct. The tool is now properly calibrated. The issue is the step-change in output, not the calibration accuracy.
Edge cases include situations where calibration drift was severe, meaning the correction should create a large shift. CIDR captures this correctly because the question is not whether the calibration was right but whether the production output discontinuity creates downstream problems. If parts produced before and after calibration are never mixed in the same assembly, CIDR is informational but lower-risk. If parts are mixed, CIDR becomes high-priority because dimensional mismatch in assemblies creates fit and function defects. Minimum sample is 15 calibration events per measurement period.
Proposed formula, pending validation pilots.