Definition
Measures the average magnitude of production process parameter shift that occurs within two hours of an automated maintenance event, expressed as a fraction of each parameter's operating range.
The Measurement Gap
Automated maintenance is increasingly common in modern manufacturing: automated lubrication systems, self-cleaning cycles, auto-calibration routines, and scheduled filter replacements all execute without human intervention. These actions are tracked in the maintenance system as completed events, and the production system records process parameters continuously. But nobody compares the process parameters before and after the automated maintenance event to see if the maintenance itself caused a disturbance.
The measurement gap matters because production engineers often see unexplained process parameter shifts, such as a temperature change, a pressure fluctuation, or a speed variation, and compensate for them by adjusting process settings. If the shift was caused by an automated maintenance event that the production team does not know about, the compensation is treating a symptom without understanding the cause. Over time, these unattributed compensations accumulate, making process troubleshooting more difficult and potentially masking the need for maintenance timing coordination. AMPSI provides the data to determine which automated maintenance types cause the most process disruption and whether the timing of those maintenance actions should be coordinated with production parameter monitoring.
Formula
AMPSI averages the magnitude of process parameter shifts across all monitored parameters and all automated maintenance events in the measurement period.
AMPSI = (1/N) times Sum over i of (1/P) times Sum over p of |Param_p_post_i minus Param_p_pre_i| / Range_p
Where Param_p_post_i is the value of process parameter p measured two hours after automated maintenance event i. Param_p_pre_i is the value of process parameter p measured immediately before event i. Range_p is the normal operating range of parameter p (maximum minus minimum under steady-state production). P is the number of monitored process parameters. N is the number of automated maintenance events in the measurement period.
An AMPSI of 0 means no process shift from maintenance, indicating that automated maintenance actions have no measurable effect on production parameters. Higher values indicate more disturbance, with the metric expressed as a dimensionless fraction of the operating range. Compare AMPSI across auto-maintenance types to identify which maintenance actions cause the most process disruption.
Edge cases include process parameter shifts from other causes during the two-hour window, such as product changeovers or material lot changes. Exclude maintenance events that coincide with other known process changes to isolate the maintenance effect. Some maintenance actions cause an immediate shift followed by a gradual return to baseline. The two-hour window captures the acute shift, and recovery time should be tracked as a supplementary metric. Maintenance during non-production periods yields no process parameters to measure. Minimum sample is 20 automated maintenance events per type per measurement period.
Proposed formula, pending validation pilots.