Definition
RRQ measures the area under the functionality curve during a disruption-recovery cycle, normalized against the throughput that perfect instant recovery would have delivered.
The Measurement Gap
MTTR was built for a world where assets are binary (up or down) and treats a 2-hour repair that restores 40% throughput the same as a 2-hour repair that restores 95%. Real recoveries are curves: ramps, partial loads, stabilization periods. OEE averages performance over reporting periods and dilutes the disruption into invisibility. Availability has the same binary problem. The maintenance log says 1.5 hours; the production log says the plant lost the equivalent of 4.2 hours across a 6-hour window. Real recoveries are curves, a compressor comes back online but takes 45 minutes to reach full load, a packaging line restarts but runs at reduced speed for two shifts. Availability has the same binary problem: the asset is either "up" or "down" with no concept of "up but limping" or "up but downstream hasn't stabilized." The gap is not in the maintenance team's performance. It is in the measurement system's vocabulary.
Decision Supported:
Which recovery practices (partial-operation protocols, operator load-shedding, automated failover) actually preserve production versus which ones merely rush the repair while the plant bleeds.
Formula
Plain language: Add up throughput delivered minute by minute from disruption onset to full recovery. Divide by what perfect instant recovery would have produced over the same window.
Notation:
RRQ = ∫(t₀ to tᵣ) Q(t) dt / [ Q_baseline × (tᵣ − t₀) ]
Variables:
| Variable | Definition | Unit |
|---|---|---|
| Q(t) | Actual system throughput or functionality at time t, as a fraction of baseline | Fraction (0–1) |
| Q_baseline | Normal steady-state throughput before the disruption | Production units/hour |
| t₀ | Moment functionality starts dropping (not when the work order opens) | Timestamp |
| tᵣ | Moment full functionality is restored (recommended: 95% of baseline) | Timestamp |
| Integral | Sum of throughput sampled at regular intervals (every 5–15 minutes) over the window | Production-units |
RRQ = 1.0 means instant complete recovery. Most real events fall between 0.3 and 0.8.
Proposed formula, pending validation pilots.