Compliance Scheduling Segregation Index (CSSI-DC)

GMI-DC-017Data CentersPilot-ReadyPattern R-1: Segregation Index

Definition

CSSI-DC measures whether AI scheduling algorithms maintain the same on-time completion rate for regulatory-required maintenance tasks as they achieve for the overall work order population, detecting the specific failure mode where optimization logic deprioritizes compliance work in favor of AI-weighted efficiency objectives.

The Measurement Gap

Work order completion dashboards report overall on-time rates that blend regulatory and non-regulatory work into a single aggregate metric. When AI scheduling optimizes for equipment-level priorities (predictive conditions, criticality scores, resource efficiency) it applies the same optimization logic to all work orders including those with hard regulatory deadlines. The optimizer does not inherently distinguish between a window cleaning task that can slide and an NFPA 110 generator test with a fixed compliance deadline. PM compliance rates are aggregate measures that obscure whether regulatory work is completing on time or being systematically deferred. This gap becomes apparent only during audits, when regulators find that compliance deadlines were missed despite a facility reporting 95% PM compliance overall.

Decision Supported:

CSSI-DC determines whether the AI scheduling system is maintaining appropriate priority segregation between regulatory-mandated work and optimization-driven work, or whether its objective function is inadvertently subordinating compliance obligations to operational efficiency metrics.

Formula

Plain language: Compute the on-time completion rate for all work orders tagged with regulatory compliance codes, then compute the on-time completion rate for all work orders. Divide the regulatory rate by the overall rate. A ratio of 1.0 means regulatory work completes on time at the same rate as all other work. Below 1.0 means regulatory work is relatively deprioritized.

Notation:

CSSI-DC = OTR_regulatory / OTR_overall

Variables:

Variable Definition Unit
OTR_regulatory On-time completion rate for work orders tagged with regulatory compliance codes (NFPA 110, NFPA 25, EPA 608, OSHA, local electrical code): count of completed on-time / total due in period Percentage (0–100%)
OTR_overall On-time completion rate for all work orders in the same measurement period Percentage (0–100%)

Tag work orders with the applicable regulatory code at creation, not retrospectively. If the CMMS does not have regulatory compliance codes, that tagging gap must be addressed before CSSI-DC can be computed reliably. Exclude work orders preempted by genuine emergency response from both numerator and denominator, an emergency generator failure that displaces a scheduled NFPA test should be handled as rescheduling, not a compliance miss, provided the test is rescheduled within the regulatory grace period. Use rolling 6-month windows for programs with seasonal compliance requirements to avoid denominator distortion.

Proposed formula, pending validation pilots.

At a Glance

Unit
Ratio
Trend Direction
Higher; regulatory on-time rate meets or exceeds overall on-time rate
Reporting Frequency
Monthly; rolling 6-month window for seasonal programs
Category
Regulatory Compliance
← Compliance Margin Remaining (CMR)Knowledge Base Root-Cause Alignment (KBRCA) →

Assess Your Organization

The AI-GPS Assessment evaluates your AI governance maturity and recommends KPIs like this one for your implementation roadmap.

Take the Free AI-GPS Assessment