Definition
IDCR measures the percentage of defined inspection domain points (all locations required by the maintenance plan and applicable regulations) that autonomous inspection systems actually covered with data meeting quality thresholds during a given mission.
The Measurement Gap
Autonomous inspection systems are typically evaluated on mission completion rates and alarm generation counts. Neither of which distinguishes whether the system actually visited all required locations versus only the locations that were accessible. Traditional human inspection relied on technician sign-off checklists that confirmed physical presence at each location; autonomous systems substitute digital logs that may not track coverage at the granularity required to verify regulatory compliance. Regulatory frameworks for NFPA 110, NFPA 25, and EPA 608 inspection programs specify element-level coverage requirements that aggregate coverage statistics cannot confirm. A system reporting "96% mission completion" may have skipped the three locations in a hot aisle that are hardest to access and most likely to have thermal anomalies.
Decision Supported:
IDCR determines whether autonomous inspection missions are achieving coverage sufficient to meet both operational surveillance requirements and regulatory compliance obligations, or whether systematic coverage gaps require mission redesign or supplemental manual inspection.
Formula
Plain language: Divide the number of inspection points where the autonomous system collected data meeting quality thresholds by the total number of inspection points required by the maintenance plan and applicable regulations. Express as a percentage. Track the regulatory subset separately from the operational total because the stakes and acceptable failure rates are different.
Notation:
IDCR = (Inspection_points_covered / Inspection_points_required) × 100
Variables:
| Variable | Definition | Unit |
|---|---|---|
| Inspection_points_covered | Count of required inspection domain locations where the system collected data that met the defined quality threshold (e.g., image resolution ≥ minimum, thermal sensor reading within calibration range, no data gap at that location) | Count |
| Inspection_points_required | Total count of inspection domain locations required by the facility maintenance plan plus applicable regulatory checklist (NFPA 110, NFPA 25, EPA 608, OSHA, local electrical code as applicable) | Count |
Track two variants: IDCR_regulatory (numerator limited to regulatory-required points; denominator = regulatory-required points only) and IDCR_operational (full domain including maintenance-plan-only points). A data point collected but failing quality threshold (blurry image, sensor out of range, data gap) does not count toward Inspection_points_covered: coverage credit requires both presence and quality. Update the domain definition when new racks are commissioned or decommissioned; a static domain list in a dynamic facility will systematically overstate coverage.
Proposed formula, pending validation pilots.